Step motor test
With this test function the step motors and the pertaining reference
switches can be checked.
ATTENTION ! Risk of breakage !
Before the test: Move needle in position “up” by handwheel.
Start test function with the key “OK”.
Check transverse motion of the step motor (X-axis).
Move step motor with the keys ï”or“ð”.
The number of steps done is indicated on the left of the arrow.
The status of the reference switch changes around the reference
position.
Check longitudinal motion of the step motor (Y-axis).
Move step motor with the keys ñ”or“ò”.
The number of steps done is indicated above the arrow.
The status of the reference switch changes around the reference
position.
step.motor tst
Press function key “ESC”.
The test is finished.
The menu Multitest appears on the display.