DURKOPP ADLER DAC basic Informations techniques Page 30

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 31
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 29
© 2012 Dürkopp Adler AG
Error, warning and information messages
DACeco
30
Degree
Code
Error or information description
Remedial measures
- Check wiring in the machine distributor and change if
necessary
- Test motor phases and check for value
Error
15
Excess sewing motor current,
internal current increase >25A
- Replace control unit
Error
16
Maximum speed exceeded
- Replace encoder
Error
17
AC RDY time-out , intermediate
circuit voltage has not reached the
defined threshold in the given time.
- Check mains voltage
- If mains voltage OK, replace control unit
Information
18
No valid data on internal and
external EEprom
- Check the connection of the Mach ID
- Turn off the control unit, wait until LEDs are off,
restart
- Update software
Information
19
No valid data on internal EEprom
- Check the connection of the Mach ID
- Turn off the control unit, wait until LEDs are off,
restart
- Update software