DURKOPP ADLER 530 Instructions d'exploitation Page 55

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 98
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 54
PWM Output test
This test function checks the function of the magnets.
Start the test function by pressing the OK”key.
Select the desired output element by pressing the keys “ñ”or“ò”.
Switch the selected output element on and off by pressing the
OK”key.
PWM output test
output
The issued value for the selected output element is displayed.
The value specifies the impulse rate for the controlling of the
output element.
Press function key “ESC to quit the test function.
Caution: Danger of injury !
Do not reach into the running machine during the function test of the
output elements.
Output element Function
PWM 1 Clamp foot magnet
PWM 2 Trimmer magnet
PWM 3 Thread wiper magnet
53
1
Vue de la page 54
1 2 ... 50 51 52 53 54 55 56 57 58 59 60 ... 97 98

Commentaires sur ces manuels

Pas de commentaire